|
 |
DVM PLUS lll
|
 |
 |
DVM Plus III offers the largest capacity in the industry with
64HP and boasts the highest COP levels. More compact size,
with larger capacity, shows the efficiency of the product.
|
 |
|
| |
 |
 |
 |
 |
 |
|
 |
| High COP |
High efficiency DVM Plus III has improved
average cooling and heating COP compared to conventional products
and achieved the world’s Top Class energy efficiency
? DHS(Digital Hybrid System) technology increased refrigerant flow
rate and evaporation enthalpy difference.
? Wide 8Ø Grooved pipe and G-Fin increased heat exchange efficiency.
? The best BLDC Motor in the industry and Optimum Fan Guard design
increased efficiency. |
 |
| The World’s Largest Capacity |
Samsung has achieved world’s largest capacity
of 64 HP by combining maximum 4 outdoor units of 8,10,12,14 and 16
HP.
Simultaneous launching of compact and high-efficiency products also
provide consumers to variety of choices according to their installation
environment. Maximum 64 variety indoor units can be connected together
for operation.
? Compact combination (8~64 HP) : Combination with the model requiring
the smallest installation space.
? High-Efficiency combination (16~56 HP) : Combination with high-efficiency
model. |
 |
| Improved Heating
Performance |
| Vapor Injection technology has been improved
heating performance at a low ambient temperature of -10ºC by
20%. |
 |
| The Smallest Foot Print
Area |
| Reducing the outdoor unit size,
compare to the conventional model, achieved world’s smallest installation
space. |
 |
| Digital Unit
Module |
Digital Unit Module combination enables
the system to alternate compressor operation to prolong each compressor’s
life cycle and improves COP with part loads
? Control the compressor capacity precisely.
? Ensure long life cycle by alternating operation of the DVI compressors.
? Improve COP using multiple heat exchangers of outdoor units at part
loads.
? System still able to conduct modulation of capacity with other DVI
compressor under emergency operation caused by failure of a compressor. |
 |
| Display Panel |
| Display window allow you to check communication/operation
status and to modify dip switch conveniently without opening control
panel. |
 |
| The World’s Longest Piping
Length |
 |
DVM PLUS III has an actual piping length of 200m, with the maximum
piping length of 45m from the first branch joint to the last indoor
unit, thereby providing convenience and flexibility for installation
for commercial buildings. You can get comfortable heating and cooling
even with long piping.
› Summary
? The longest piping length : 200m
? Total piping length: 1000 m
? From the first branch joint to the last (farthest) indoor unit :
90 m (with one piping Size Up) |
| Free Installation |
| There are no limitation on
order of outdoor unit capacity, digital unit and fixed unit when installing
the outdoor unit. |
|
| External Static
Pressure |
| To respond to a range of different installation
environments, DVM PLUS III is designed to be used even in external
static pressure of 8 mm Aq. |
 |
| Automatic Piping Length
Recognition |
| With automatic piping length
recognition, installation can be carried out without extra piping
length setup(which conventional models have to set up), and perform
the optimum operation in accordance with piping length. |
|
| Lead-Free
and RoHs |
| Refrigerant
Leakage Prevention |
| To prevent refrigerant leakage, we provide a solution
to diagnose any refrigerant leakage during product operation. Also,
changing service valves from flange type to brazed type further prevents
refrigerant leakage. |
 |
| RoHs
Compliance |
| Although RoHS restriction only applies to
small/large household electronics, IT equipment, lightings, power
train, toys and leisure/sports equipment, vending machines, Samsung
expands the RoHS restriction into its entire range of products based
on its own environmental policies. |
| Lead-Free |
| DVM Plus III is an eco-friendly product that prevents
pollution problems caused by the use of lead, by applying lead-free
indoor and outdoor PCBs. |
 |
|
|
| Digital
Hybrid System |
| DHS (Digital Hybrid System) is a brand
new concept system composed of DVI compressor, vapor injection
technology and turbo intercooler. These 3 factors together provide
highly efficient performance. |
 |
| DHS
System |
 |
DVI Compressor
DVI (Digital Vapor Injection) compressor injects optimized
mid-range pressure refrigerant to improve cooling and
heating performance and efficiency. |
 |
New G-Fin
High efficiency new G-fin improved heat transfer performance
and reinforce corrosion resistance. |
 |
Turbo Intercooler
Turbo intercooler(Shell and Tube Type) improves cooling
and heating COP and secure reliability on long piping
installation. |
 |
Fan Guard
Optimized fan guided design enhanced air flow volume which
achieved heat transfer performance without increased noise. |
 |
Ø8 Heat Exchanger
Highly efficient O8 Grooved tube has been applied to reduce
pressure loss while increasing heat transfer performance
to improve COP. |
|
|
|
| DVI Compressor |
| Efficient and reliable DVI Compressor
coupled with Vapor Injection technology has been applied to
improve cooling and heating performance and energy efficiency. |
 |
| Vapor
Injection Technology |
Improved cooling and heating performance
and COP by a new technology that injects mid-range pressure
refrigerant with two-stage compression. This technology achieved
the high heating performance and COP under the lowest temperature,
which leads the industry.
? Increase refrigerant flow rates with a new Vapor Injectiontechnology.
? Improved Sub-cooling necessary for long piping runs while
increasing cooling and heating performance and COP. |
 |
| Turbo Intercooler |
Turbo intercooler (Shell & Tube
Type) improved cooling and heating COP, to secure reliability
on long piping installation.
? Improve COP with the application of Turbo intercooler.
? Adequate sub-cooling to ensure reliable operation on installations
with long piping (200 m).
|
 |
| High Efficiency Ø8
Heat Exchanger |
Efficient Ø8 Grooved tube reduced
pressure loss while increasing heat exchange rates to improve
COP.
? Groove shape is designed to be high and slim to increase heat
transfer performance inside the tube. |
 |
| New G-Fin |
Highly efficiency new G-Fin increased
heat transfer performance, reinforced corrosion resistance,
and increased operating duration in frost condition.
? Heat transfer performance improved by 13% compared to the
conventional fin, even with the equivalent pressure loss.
? Epoxy Acrylic Coating reinforced corrosion resistance.
? Heating operation time is 1.4 times longer in frost condition
due to new G-Fin. |
 |
| Newly Designed Fan Guard |
Fan Guard has been optimized to improve
air volume and reduce noise and vibration.
? BLDC Motor, which is 2.7% more efficient than the competitors,
has been applied.
? Applied high static pressure propeller fan and the optimum
Bell Mouth form for high external static pressure.
(External static pressure: 8mmAq) |
|
|
|
|
|
|
|
|